When a wood fireplace gets a gas log set, the damper's job flips. On a wood fire it is opened for the fire and closed afterwards to stop drafts. Under a vented log set, the flue has to stay open every moment the burner or the pilot is lit, and a damper that can swing shut is a hazard rather than a convenience. Many of the gas hearths we look at in San Juan Capistrano have a damper problem nobody has noticed, because the logs still light and the flame still looks fine. This post covers what goes wrong, how it shows, and what fixing it involves.
Why the damper matters more with gas
Wood smoke announces itself. Close the damper on a wood fire and the room fills with smoke in seconds, and everyone opens it again. Gas exhaust gives far less warning. A vented log set with the damper half shut can burn for an evening, sending some of its exhaust into the room, with nothing more obvious than a headache or a stale smell. That is why makers of vented log sets, and the codes that follow them, call for a stop or clamp on the damper so the plate can never close fully while the set is installed.
What we find
- A missing clamp. The set was installed years ago, the clamp has been lost or taken off during a cleaning, and the damper now closes all the way.
- A seized pivot. Rain down an uncapped or poorly capped flue rusts the pivot and the plate. The damper sticks half open, then one day sticks shut.
- A broken linkage. The handle in the firebox moves, the plate above does not. People think the flue is open when it is not.
- A warped or rusted plate. Years of wood fires before the gas set went in left the plate bowed or eaten through. It no longer seats, and it no longer opens fully either.
- A top damper that has failed. Some chimneys have a sealing damper fitted at the top of the flue, worked by a handle in the firebox. Under a vented log set these need a lock or stop of their own, and when the hinge, the gasket or the operating line fails, the top plate can drop closed.
The signs in the room
You do not need to look into the flue to suspect a damper problem. The clues in the room:
- a dark band of soot on the brick or stone above the fireplace opening;
- a smell when the logs are running that was not there before;
- watering eyes or a headache after an evening with the fire on;
- a carbon monoxide alarm that chirps or sounds when the fireplace is in use;
- a cold draft from the fireplace when the logs are off, which tells you the plate is open (fine) but may also tell you it no longer seats when you want it closed for the summer.
If the alarm sounds, take everyone outside first. The fireplace stays off until someone has found out why.
The fixes
Which repair fits depends on what we find, but the usual ones are:
- Fitting a damper clamp that holds the plate partly open whenever the log set is in place. Often the cheapest fix and the one most often missing.
- Freeing or replacing the plate. A seized pivot can sometimes be freed; a rusted-through or warped plate is replaced with one sized to the frame.
- Removing the damper altogether. Where the log set is permanent and the owner never plans to burn wood again, the plate can be taken out so there is nothing left to close. A top-mounted sealing damper can then be fitted for summer drafts, with a stop that keeps it partly open while the set is installed.
- Repairing or replacing a top damper. New hinge, new gasket, new operating line, or a new unit if the old one has rusted beyond saving.
- Dealing with the water. If a missing cap or cracked crown rusted the damper in the first place, we point that out, because a new plate under the same rain will go the same way. A stainless cap is quoted after we measure, by size and type.
Price and the next step
Damper repair has no published price, because the parts and the access vary from one firebox to the next. Most of these problems are found on a Level 1 inspection, $160, which covers the damper, the firebox, the flue as far as we can see from below and the top from the roof. If the flue is coated in soot from a log set that has been burning badly, a sweep, from $400, comes first so we can see what we are working on. After that we write the damper figure down for you before any work starts.
Describe what you notice when you try the handle, and whether the fireplace holds logs, an insert or nothing, when you book.
Book a damper check for your gas log fireplace
While we are there
A damper visit is a good moment to look at the rest of the gas side: the pilot, the log positions, the burner ports and the shutoff key. If the logs are out of place or the burner is sooting, a gas fireplace cleaning puts that right. If you are thinking of moving to a sealed unit instead, our post on gas logs or a gas insert compares the two, and an insert removes the damper question entirely, since it vents through its own pipe.
The chimney damper repair page lists the damper work we do. For a damper you are unsure about in San Juan Capistrano or the towns around it, the contact page is the place to start; tell us what the handle does and we will take it from there.