What the camera saw, and how it gets fixed
Send us your findings
Tell us what the inspection report or camera footage showed and what the fireplace burns.
On the screen: a frame from a failing flue
The camera is a few feet above the damper, looking up. The clay tile should be a smooth, square tube of the same pale colour. Instead there is a dark line running up one face, wider at the bottom than at the top. A little higher the camera reaches a joint between two tiles, and the joint is a black gap with daylight-coloured brick showing behind it. Higher again there is a step where one tile has slipped against the next.
Each of those is a code issue, because the flue is no longer a sealed path for heat and exhaust. Heat can reach the brick and the wood beyond it, and exhaust can leak into the walls. On a gas fireplace the worry is less about heat and more about exhaust and the water vapour it carries.
Cracked and missing tiles
A single cracked tile in an otherwise sound flue can sometimes be dealt with on its own, but most of the time a crack is a sign of a bigger event: a chimney fire, an earthquake, or years of water. When the camera finds more than one, the usual fix is a new liner run inside the old tile, so the old flue becomes a protected chase rather than the vent itself.
Gaps between tiles, where the mortar has washed or burnt out, are treated the same way. Patching joints from inside is limited and hard to verify, so we tend to recommend a liner and say so plainly.
No liner, or the wrong one, behind a gas unit
This is the finding we see most in San Juan Capistrano homes. A gas insert or a log set was added to a fireplace built for wood, and either no liner was fitted or a short stub was pushed a few feet up the old flue. The unit runs, but its cool, wet exhaust condenses on the clay, eats the mortar and stains the brick outside.
The fix is the liner the unit's maker specifies, run the full height of the chimney with a proper cap at the top. If the unit is old enough that it is not worth relining around, replacing it with a new insert and its own vent kit is often the better spend.
The top of the flue
The camera also shows what comes in from above. Rust streaks, wet tile or leaves at the bottom point to a missing or broken cap, a crown that is letting water in, or a leak at the roof. Those get fixed alongside the flue work, because a new liner under a leaking top is money spent twice.
Prices for the usual fixes
These are the flue and top-of-chimney fixes we publish prices for. The cap, last, is quoted after we measure. Relining, crown work, dampers and chase covers are written up separately after we have seen the chimney.
- Camera run to confirm the flue findings
- $370
- Sealed gas unit replacing a failing setup, vent kit included
- $2,650 to $5,300
- Leak traced to its source and sealed
- $530 to $3,200
- Sheet metal cricket behind the stack
- $425 to $960
- Diverter plus every flashing piece renewed
- $640 to $1,600
- Cap over the flue top, fitted
- Quoted after we measure
Each range follows the size of the chimney and the parts it needs. Your written figure names the exact work.
Flue repair questions
Can a flue with one cracked tile still be used?
It depends where the crack is and what burns below it. The report says whether the fireplace is safe to use, should be repaired soon, or should stay off until fixed, and why.
Why does a gas insert need its own liner?
Gas exhaust is cool and wet. In a large clay flue it condenses and attacks the mortar. Insert makers specify a liner of a set size running the full height of the chimney so the exhaust leaves quickly and the unit draws outside air properly.
Can you price from footage another company shot?
Not always. If your footage is recent and clear, we can price from it and confirm on the day. If it is old or does not show the full height, we run the camera again first.
Is a new liner always the answer?
No. A small, local fault in an otherwise sound flue can sometimes be repaired on its own. We tell you which situation you are in and why.
Can the cap and the liner be done in one visit?
Usually, yes. The liner ends at a plate on top of the chimney and the cap sits over it, so we plan them as one job.
Bring us what the camera found
Use the contact page to describe the findings from your report and what your fireplace burns. We call back to set a visit and write down the fixes.